RHONE-POULENC BASIC CHEMICAL CO -- SODIUM BICARBONATE -- 6810-00-290-5574
=====================  Product Identification  =====================

Product ID:SODIUM BICARBONATE
MSDS Date:04/25/1994
FSC:6810
NIIN:00-290-5574
MSDS Number: BWPYJ
=== Responsible Party ===
Company Name:RHONE-POULENC BASIC CHEMICAL CO
Address:1 CORPORATE DRIVE
Box:881
City:SHELTON
State:CT
ZIP:06484
Country:US
Info Phone Num:203-925-3300
Emergency Phone Num:203-925-3300
CAGE:RHNEP
=== Contractor Identification ===
Company Name:JEM SALES INC   INCHEMCO DIV
Address:430 LAVENDER DR
Box:City:ROME
State:GA
ZIP:30165-2262
Country:US
Phone:706-232-1709
CAGE:0AZD7
Company Name:RHONE-POULENC BASIC CHEMICAL CO
Address:1 CORPORATE DR
Box:881
City:SHELTON
State:CT
ZIP:06484
Country:US
Phone:203-925-3300
CAGE:RHNEP

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM BICARBONATE
CAS:144-55-8
RTECS #:VZ0950000
Fraction by Wt: 100%
Other REC Limits:NONE SPECIFIED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL RAT) IS >4220 MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MILDLY TOXIC BY INGESTION. DOSES OVER
    5 GM/KG CAN CAUSE ALKALOSIS & EXPANSION IN EXTRACELLULAR FLUID
    VOLUME W/EDEMA. APPLICATION OF LARGE AMOUNTS TO SKIN MAY CAUSE
    ALKALOSIS. IRRITATING TO EYES, SKIN,  RESPIRATORY TRACT.
Explanation of Carcinogenicity:THIS PRODUCT DOES NOT CONTAIN ANY
    INGREDIENT DESIGNATED BY IARC, NTP, ACGIH OR OSHA AS A PROBABLE
    HUMAN CARCINOGEN.
Effects of Overexposure:MAY CAUSE EYES, SKIN AND RESPIRATORY TRACT
    IRRITATION.IF SWALLOWED, MAY CAUSE NAUSEA,VOMITING AND PAIN.IN
    LARGE DOSES, IT MAY CAUSE ALKALOSIS.
Medical Cond Aggravated by Exposure:SKIN IRRITATION MAY BE AGGRAVATED
    IN PERSONS WITH EXISTING SKIN LESIONS. BREATHING OF DUST MAY
    AGGRAVATE ACUTE OR CHRONIC ASTHMA AND OTHER CHRONIC PULMONARY
    DISEASE.

=======================  First Aid Measures  =======================

First Aid:IF ANY IRRITATION PERSISTS OR IS SEVERE, SEE A DOCTOR. 
    EYE:FLUSH W/WATER 15 MIN, HOLD LIDS OPEN. SKIN:REMOVE CONTAMINATED
    CLOTHING AND LAUNDER BEFORE REUSE. WASH WITH SOAP & WATER.
    INHALED:REMOVE TO  FRESH AIR. RESTORE/AID BREATHING AS NEEDED.
    INGESTED:(LARGE QUANTITY) IMMEDIATELY GIVE 2 LARGE GLASSES OF MILK
    OR WATER AND INDUCE VOMITING. (NOTHING BY MOUTH IF UNCONSCIOUS.)
    GET IMMED. MEDICAL ATTN.

=====================  Fire Fighting Measures  =====================

Flash Point:NON-COMBUSTIBLE
Extinguishing Media:THIS PRODUCT IS USED AS A DRY POWDER EXTINGUISHING
    AGENT SUITABLE FOR ALL CLASSES OF FIRE.
Fire Fighting Procedures:BECAUSE CARBON DIOXIDE GAN MAY BE PRESENT,
    WEARING A NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS MAY BE
    REQUIRED.
Unusual Fire/Explosion Hazard:IF EXTREMELY LARGE QUANTITIES ARE
    INVOLVED, SIGNIFICANT LEVEL OF CARBON DIOXIDE MAY BE GENERATED.
    SODA ASH PRODUCED AT >200F IS A RESPIRATORY AND SKIN IRRITANT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:TO EXTENT POSSIBLE, CLEA UP SPILLAGE USING
    SHOVELS, SWEEPING OR VACUUM. AVOID DUST GENERATION. PLACE IN
    APPROPRIATE CONTAINERS FOR DISPOSAL. FLUSH AREA W/WATER. DO NOT
    FLUSH MATERIAL TO PUBLIC SEWER S YSTEM OR ANY WATERWAYS.
    DECONTAMINATE TOOLS.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:MATERIAL IS GENERALLY REGUARDED AS
    SAFE FOR HUMANS & ANIMALS. CONTAINERS SHOULD BE STORED IN A COOL,
    DRY AREA AWAY FROM SOURCES OF HEAT OR FLAME.
Other Precautions:STORE AWAY FROM ACIDS. LONG-TERM STORAGE MAY RESULT
    IN CAKING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN DUSTING CONDITIONS,USE A NIOSH/MSHA APPROVED
    DUST MASK IF CONCENTRATION EXCEEDS SUGGESTED EXPOSURE LIMITS. USE
    POSITIVE PRESSURE SUPPLIED AIR OR SELF-CONTAINED BREATHING
    APPARATUS FOR EMERGENCY OR	OTHER CONDITIONS NEEDING MORE
    PROTECTION
Ventilation:PROVIDE ADEQUATE VENTILATION. USE LOCAL EXHAUST AS NEEDED
    TO MAINTAIN AIRBORNE EXPOSURE BELOW CONTROL LIMITS.
Protective Gloves:CHEMICAL RESISTANT GLOVES & BOOTS
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS
Other Protective Equipment:MAINTAIN A SINK, EYE WASH STATION AND SAFETY
    SHOWER IN WORK AREA. HAVE OXYGEN READILY AVAILABLE. WORK CLOTHING.
Work Hygienic Practices:MFR: ? HMIS:USE STRICT CHEMICAL HYGIENE
    PRACTICE. AVOID UNNECESSARY EXPOSURE. WASH THOROUGHLY BEFORE EATING
    OR DRINKING.
Supplemental Safety and Health
PROTECTIVE EQUIPMENT SHOULD BE USED DURING THE FOLLOWING
    PROCEDURES:MANUFACTURE OR FORMULATION OF THIS PRODUCT, REPAIR &
    MAINTENANCE OF CONTAMINATED EQUIPMENT, CLEAN UP OF LEAKS & SPILLS,
    ANY ACTIVITY  THAT MAY RESULT IN EXPOSURES TO CONCENTRATIONS THAT
    EXCEED EXPOSURE LIMITS.

==================  Physical/Chemical Properties  ==================

HCC:N1
NRC/State Lic Num:NONE
Melt/Freeze Pt:M.P/F.P Text:DECOMPOSES
Decomp Temp:Decomp Text:518F,270C
Solubility in Water:9.6 G/ 100 G WATER
Appearance and Odor:WHITE GRANULAR SOLID/ODORLESS - PH OF 1% SOLUTION =
    8.5

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:NO
REACTS W/WEAK ACIDS FORMING SALT, WATER & CARBON DIOXIDE GAS &
    RELEASING HEAT.
Stability Condition to Avoid:HYGROSCOPIC; PROTECT FROM MOISTURE. KEEP
    AWAY FORM HEAT.
Hazardous Decomposition Products:AT TEMPERATURE OF 190F OR HIGHER,
    CARBON DIOXIDE GAS IS GIVEN OFF TO ATMOSPHERE. RESULTING DUST IS
    IRRITATING.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.